SoundBarrier™ — Sound Pressure Levels

We tested our SoundBarrier™ with a .750” (19.1 mm) Air Miser™ air wipe (without material) at our factory to determine general noise reduction results that could be expected in use. The sound pressure test was conducted at approximately 6' (1.83 m) at an ambient sound pressure of 68 dB.

Air
Flow
dB* Level of
Air Miser™ only
dB* Level with
SoundBarrier™
dB*
Reduction
10 PSI
(0.7 bar)
74.5 68.5 (6.0)
20 PSI
(1.4 bar)
74.5 68.5 (6.0)

30 PSI
(2.1 bar)

74.5 68.5 (6.0)

40 PSI
(2.8 bar)

74.8 68.8 (6.0)
50 PSI
(3.5 bar)
75.0 69.0 (6.0)
60 PSI
(4.2 bar)
76.0 70.0 (6.0)
70 PSI
(4.9 bar)
77.5 70.0 (7.5)
80 PSI
(5.6 bar)
80.0 70.5 (9.5)
 
Tested at Huestis Industrial factory, results may vary. *.750” (19.1 mm) empty Air Miser.

home productsnewsnoticessupportour storyfeaturestech specs.pdf filefaq'stech tipsreceive infocontacts

© 2001 Huestis Industrial. All rights reserved. Specifications subject to change without notice.
Please contact us at 401.253.5500 (M-F, 8:00 am-5:00 pm, EST, USA) or sales@huestis.com for sales or technical assistance.