Remanufactured GE AMX Portables — Remanufacturing Process

remanufacted GE AMX PortablesHuestis Medical remanufactures GE AMX portables under a thorough electronic, mechanical, and cosmetic program. All electronics are removed, tested, and fully calibrated, including wiring harnesses and circuit board repairs, to ensure reliability.

In-house TIG welding reinforces common stress points on frame and chassis while a strengthened cassette drawer and new front casters offer solid support. New drive chains and brake pads provide dependable service. Differential axle, motor and drive gears are fully evaluated and replaced if necessary.

Heavily reinforced column support is fitted with new counterweight cables and is given a constant friction rotational lock retrofit for all AMX-110's and AMX II's. Other new components include a Delrin latch bar, retractable hand-switch cord, low/ high voltage cables, control lights, dials, decals, and maintenance-free Lead-Calcium battery upgrade.


GE AMX-110, AMX-II, AMX-III — NEW Replacement Parts

  • Relays 3K1 and 8K1.
  • Manual and exposure guide.
  • Control panel overlay.
  • KV and mAs knobs.
  • Battery high/low knob.
  • Control panel indicator lights.
  • Collimator knobs and crosshair window.
  • Lead-Calcium batteries (26 amp/hr).
  • Upgraded column reinforcement modification.
  • Upgrade to “AMX-III style” column friction brake (where applicable).
  • Steel “counterpoise” cables in column.
  • Front casters.
  • Upgraded wrap-around bumper.
  • Drive brake pads.
  • Drive chains and tube arm chain.
  • Upgraded stainless steel drive handle.
  • Forward/reverse switch.
  • Upgraded handswitch coil cord and handswitch assembly.
  • Upgraded remote field light.
  • High voltage cables.
  • Collimator cable and rotor cable.
  • Upgraded Delrin latch bar.

GE AMX-110, AMX-II, AMX-III — Tested, Reconditioned, and Replaced Items

  • Unit is completely disassembled for thorough inspection.
  • Cord reel for charging rebuilt.
  • Main chassis pan inspected and reinforced.
  • High voltage transformer inspected.
  • All printed circuit boards inspected and tested.
  • Switches and circuit breakers.
  • Collimator assembly tested and inspected.
  • X-ray tube tested and inspected.
  • Front caster mounts.
  • Cassette drawer hinges/ latches upgraded to AMX-III style and reinforced (where applicable).
  • Speed control potentiometer and spring.
  • All bearings are inspected and replaced as needed.
  • All painted surfaces are straightened, filled, sanded, and painted.

GE AMX-IV — NEW Replacement Parts

  • High voltage cables.
  • Collimator cable.
  • Rotor cable.
  • Control cable.
  • Handswitch coil cord and handswitch assembly.
  • Steel “Counterpoise” cables in column.
  • New batteries (Hawker Genesis 26 amp/hr).
  • Top shroud overlays (3).
  • Collimator crosshair window.
  • Collimator face decal.
  • Rubber bumpers and wear strips.
  • Field light switch.
  • Delrin latch pin.
  • Manual and exposure guide.

GE AMX-IV — Tested, Reconditioned, and Replaced Items

  • Unit is completely disassembled for thorough inspection.
  • Front caster mounts.
  • Cassette drawer hinges.
  • All bearings are inspected and replaced as needed.
  • High voltage transformer inspected.
  • All printed circuit boards inspected and tested.
  • Main chassis pan inspected and repaired.
  • X-ray tube tested and inspected.
  • Collimator assembly tested and inspected.
  • All painted surfaces are straightened, filled, sanded, and painted.

All Systems — Full Documentation

  • Each unit comes with a complete set of manuals.
  • Included operator manual.
  • Included service documentation.
  • Included electrical schematics.
  • Included parts diagrams.

Miscellaneous AMX Calibrations — All Units

  • Electronically each unit is calibrated on every mAs and kVp station prior to shipping.
  • Light to x-ray field is set to meet specifications.
  • Ground fault leakage tests are performed to assure proper grounding of all components.
  • In addition to the major quality control steps during the remanufacturing process, all units are subjected to a final quality control procedure.
  • All components are checked to assure systemic compliance with G.E. specifications.

Column Details — All Units

  • As manufactured, the column was bolted down by thin gauge aluminum flanges at the base of the outer column. Huestis Medical no longer uses the thin aluminum flanges.
  • We have a four corner structured support mechanism that has a minimum life span of three times that of the G.E. original system.
  • With the column supported correctly, the stress on the rest of the system is universally reduced.

Caster Mount Assemblies — All Units

  • The caster mounts are held on the main frame with two (2) 1/4 x 20 bolts on each side.
  • Huestis Medical structurally reinforces this area with four (4) 1/4 x 20 bolts.
  • This is an extremely important area because the weight of the column, tube, collimator and high voltage cables are on this area.

Lower Frame Details — All Units

  • The lower frame connecting the caster assemblies is an aluminum base — a common area of stress in the corner of the sub frame box assembly or chassis. We often find these areas cracking on the original aluminum welds.
  • Huestis Medical reinforces this assembly with 3/4” welded steel angle iron.
  • This important structural modification doubles the amount of material in this area.

 

You may also view GE AMX Remanufacturing Steps in .PDF format.

 


Related Links

Remanufactured GE AMX Portable Models
Remanufactured GE AMX Portable Remanufacturing Steps
Remanufactured GE AMX Portable Warranty
Remanufactured GE AMX Portable User's Listing
Remanufacturing Capabilities — Imaging Excellence


home productsnewsnoticessupportour storyfeaturestech specs.pdf filefaq'stech tipsreceive infocontacts

© 2001 Huestis Medical. All rights reserved. Specifications subject to change without notice.
Please contact us at 401.253.5500 (M-F, 8:00 am-5:00 pm, EST, USA) or sales@huestis.com for sales or technical assistance.